Description
Enhance the strength and durability of your structures with TCI PrecurStrong Carbon Strips, a pre-cured carbon fiber laminate designed to reinforce and upgrade various structural elements. Easy to apply with TCI PrecurStrong 400-SA, an adhesive epoxy, it offers a reliable solution for addressing increased live and dead loads, accommodating changes in building utilization, and enhancing overall structural capacity.
Key Advantages
- Increases live and dead loads in structures
- Enhances traffic capacity on bridges and viaducts
- Quick and easy installation
- Allows flexibility for changes in building utilization or industrial machinery layout
- Enables the removal of walls, columns, or sections of floor slabs
Key Features
- Unidirectional, high-strength, high-modulus CFRP strip
- High strength-to-weight ratio
- Lightweight, adding negligible dead load to the structure
- Non-corrosive, non-magnetic, and non-conductive
- TCI PrecurStrong 400-SA is low viscosity with long pot life characteristics
- Superior tensile and flexural strength
Applications
- Buildings
- Bridges
- Tanks and structures
- Parking garages
- Chimneys
- Piers/wharfs
- Tunnels
- Beams
Specifications
| TCI PrecurStrong Carbon Fibre | |
|---|---|
| Physical Properties | Typical Test Value |
| Tensile Strength | 400 KSI (2.758 MPA) |
| Tensile Modulus | 24 MSI (165.474 GPA) |
| Elongation at Break | 1.70% |
| Fibre Volume Content | > 68% |
| Temperature Resistance | 300° F (149° C) |
| Thickness | 0.0472“ (1.2mm) |
| Standard Width | 1.97”, 3.15”, and 3.94” (50, 80, and 100 mm) |
| TCI 400-SA - Cured 24 hrs @ 60°C | |
|---|---|
| Typical Test Properties | Typical Test Value |
| Tensile Strength | 10,050 PSI (69.3 MPA) |
| Tensile Modulus | 406 KSI (2,800 MPA) |
| Elongation at Break | 7.5% |
| Flexural Strength | 16,900 PSI (116.5 MPA) |
| Flexural Modulus | 478 KSI (3,296 MPA) |
| Glass Transition Temperature Tg | 94° C (201° C) |